Products - (25001 Products)
Schneider Electric - 3 Amp, 480Y/277 Volt, 3 Pole, Clip Mount C60BP - Branch Protection Circuit Breaker - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG
Item #: 46119970
Brand: Schneider Electric
Model #: M9F43303
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
C60BP - Branch Protection
Amperage
3
Number of Poles
3
Breaking Capacity
6 kA @ 440 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC; 14 kA @ 240 VAC; 10 kA @ 480Y/277 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
Clip
Voltage
480Y/277 V
Wire Size (AWG)
18-8
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Height (Decimal Inch)
4.0600
Overall Length (Decimal Inch)
2.8300
Overall Width (Decimal Inch)
2.1300
For Use With
OEM Panel
Standards Met
UL 489; IEC; CSA; CCC
Reset Actuator Type
Toggle Switch
Schneider Electric - 3 Amp, 500 VDC, 2 Pole, Clip Mount C60H-DC Circuit Breaker - Supplementary Protection for Direct Current - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-4, 18-6, 18-8 AWG
Item #: 46117081
Brand: Schneider Electric
Model #: M9U21203
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
C60H-DC - Supplementary Protection for Direct Current
Amperage
3
Number of Poles
2
Breaking Capacity
20 kA @ 220 VDC; 10 kA @ 440 VDC; 6 kA @ 500 VDC; 5 kA @ 12-500 VDC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
Clip
Voltage
500 VDC
Wire Size (AWG)
18-4; 18-6; 18-8
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Height (Decimal Inch)
3.1900
Overall Length (Decimal Inch)
2.8300
Overall Width (Decimal Inch)
1.4200
For Use With
OEM Panel
Standards Met
UL 1077; IEC; CCC
Reset Actuator Type
Toggle Switch
Schneider Electric - 3 Amp, 500 VDC, 2 Pole, Clip Mount C60H-DC Circuit Breaker - Supplementary Protection for Direct Current - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-4, 18-6, 18-8 AWG
Item #: 46111373
Brand: Schneider Electric
Model #: M9U31203
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
C60H-DC - Supplementary Protection for Direct Current
Amperage
3
Number of Poles
2
Breaking Capacity
20 kA @ 220 VDC; 10 kA @ 440 VDC; 6 kA @ 500 VDC; 5 kA @ 12-500 VDC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
Clip
Voltage
500 VDC
Wire Size (AWG)
18-4; 18-6; 18-8
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Height (Decimal Inch)
3.1900
Overall Length (Decimal Inch)
2.8300
Overall Width (Decimal Inch)
1.4200
For Use With
OEM Panel
Standards Met
UL 1077; IEC; CCC
Reset Actuator Type
Toggle Switch
Schneider Electric - 3 Phase, 220 to 600VAC, 3 Pole, 4X, Enclosed Cam & Disconnect Switch - 3 Wires
Item #: 69680304
Brand: Schneider Electric
Model #: MD3604X
Exact Tooling IR#: 04
Product Specifications
Enclosure Type
Enclosed
Number of Phases
3
Amperage
60
Voltage
220-600 VAC
Horsepower at 3 Phase
20 @ 240 V; 40 @ 480 V; 40 @ 600 V
Number of Poles
3
Number of Wires
3
Overall Depth (Decimal Inch)
4.3700
NEMA Enclosure Rating
4X
Overall Height (Decimal Inch)
8.2700
Overall Width (Decimal Inch)
4.9400
Standards Met
IEC Standard 60947-3; UL File E164864
Schneider Electric - 3 Phase, 220 to 600VAC, 3 Pole, 4X, Enclosed Cam & Disconnect Switch - 3 Wires
Item #: 69680312
Brand: Schneider Electric
Model #: MD3304X
Exact Tooling IR#: 04
Product Specifications
Enclosure Type
Enclosed
Number of Phases
3
Amperage
30
Voltage
220-600 VAC
Horsepower at 3 Phase
20 @ 480 V; 25 @ 600 V; 7.5 @ 240 V
Number of Poles
3
Number of Wires
3
Overall Depth (Decimal Inch)
4.3700
NEMA Enclosure Rating
4X
Overall Height (Decimal Inch)
6.3800
Overall Width (Decimal Inch)
3.9000
Standards Met
IEC Standard 60947-3; UL File E164864
Schneider Electric - 30 Amp Circuit Breaker Auto Time Delay - Use with Vigirex Ground-Fault Relays
Item #: 56751845
Brand: Schneider Electric
Model #: 56390TD
Exact Tooling IR#: 04
Product Specifications
Accessory Type
Auto Time Delay
For Use With
Vigirex Ground-Fault Relays
Amperage
30
Schneider Electric - 30 Amp, 1 Pole, DIN Rail Mount Standard Circuit Breaker - Multiple Breaking Capacity Ratings, 14-2 (Copper) AWG, 3 Inch Deep x 3.19 Inch High x 0.71 Inch Wide
Item #: 69660082
Brand: Schneider Electric
Model #: MG17427
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Standard Circuit Breaker
Amperage
30
Number of Poles
1
Breaking Capacity
10 kA @ 120/240 VAC; 5 kA @ 277 VAC
Mounting Type
DIN Rail Mount
Wire Size (AWG)
14-2 (Copper)
Overall Depth (Decimal Inch)
3
Overall Height (Decimal Inch)
3.1900
Overall Width (Decimal Inch)
0.7100
For Use With
OEM Panel
Schneider Electric - 30 Amp, 120/240 VAC, 1 Pole, DIN Rail Mounted Miniature Circuit Breaker - Thermal Magnetic Trip, 10 kA at 240 VAC Breaking Capacity, 14-2 AWG, 76mm Deep x 81mm High x 18mm Wide
Item #: 56785942
Brand: Schneider Electric
Model #: 60215
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
30
Number of Poles
1
Breaking Capacity
10 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
DIN Rail Mounted
Voltage
120/240 VAC
Wire Size (sq mm)
1-35
Wire Size (AWG)
14-2
Durability
4000 Cycles
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Depth (Decimal Inch)
3
Overall Depth (mm)
76
Overall Height (mm)
81
Overall Height (Decimal Inch)
3.1900
Overall Width (mm)
18
Overall Width (Decimal Inch)
0.7100
Standards Met
CE Marked; CSA C22.2 No. 5.1 Circuit Breakers: File No. 179014; HID (High Intensity Discharge) Rated; IEC 60947-2; UL 489 Circuit Breakers: File No. E215117; UL Listed for SWD Applications
Reset Actuator Type
Handle
Schneider Electric - 30 Amp, 120/240 VAC, 1 Pole, DIN Rail Mounted Miniature Circuit Breaker - Thermal Magnetic Trip, 10 kA at 240 VAC Breaking Capacity, 14-2 AWG, 76mm Deep x 81mm High x 18mm Wide
Item #: 56838956
Brand: Schneider Electric
Model #: 60232
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
30
Number of Poles
1
Breaking Capacity
10 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
DIN Rail Mounted
Voltage
120/240 VAC
Wire Size (sq mm)
1-35
Wire Size (AWG)
14-2
Durability
4000 Cycles
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Depth (Decimal Inch)
3
Overall Depth (mm)
76
Overall Height (mm)
81
Overall Height (Decimal Inch)
3.1900
Overall Width (mm)
18
Overall Width (Decimal Inch)
0.7100
Standards Met
CE Marked; CSA C22.2 No. 5.1 Circuit Breakers: File No. 179014; HID (High Intensity Discharge) Rated; IEC 60947-2; UL 489 Circuit Breakers: File No. E215117; UL Listed for SWD Applications
Reset Actuator Type
Handle
Schneider Electric - 30 Amp, 125 VDC, 240 VAC, 60 VDC, 1 Pole, DIN Rail Mount, Fixed Mount Miniature Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 73mm Deep x 107mm High x 18mm Wide
Item #: 69528602
Brand: Schneider Electric
Model #: 60132
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
30
Number of Poles
1
Breaking Capacity
10 kA @ 120 VAC; 10 kA @ 240 VAC; 5 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Tunnel
Mounting Type
DIN Rail Mount; Fixed Mount
Voltage
125 VDC; 240 VAC; 60 VDC
Durability
20000 Cycles
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Depth (mm)
73
Overall Height (mm)
107
Overall Width (mm)
18
Standards Met
CSA C22.2 No. 5.2; IEC 60947-2; RoHS Compliant; UL 489
Reset Actuator Type
Handle
Schneider Electric - 30 Amp, 125 VDC, 240 VAC, 60 VDC, 1 Pole, DIN Rail Mount, Fixed Mount Miniature Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 73mm Deep x 107mm High x 36mm Wide
Item #: 69528560
Brand: Schneider Electric
Model #: 60149
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
30
Number of Poles
1
Breaking Capacity
10 kA @ 125 VDC; 10 kA @ 240 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC; 6 kA @ 440 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Tunnel
Mounting Type
DIN Rail Mount; Fixed Mount
Voltage
125 VDC; 240 VAC; 60 VDC
Durability
20000 Cycles
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Depth (mm)
73
Overall Height (mm)
107
Overall Width (mm)
36
Standards Met
CSA C22.2 No. 5.2; IEC 60947-2; RoHS Compliant; UL 489
Reset Actuator Type
Handle
Schneider Electric - 30 Amp, 125 VDC, 240 VAC, 60 VDC, 1 Pole, DIN Rail Mount, Fixed Mount Miniature Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 73mm Deep x 107mm High x 36mm Wide
Item #: 69528487
Brand: Schneider Electric
Model #: 60166
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
30
Number of Poles
1
Breaking Capacity
10 kA @ 240 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC; 6 kA @ 440 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Tunnel
Mounting Type
DIN Rail Mount; Fixed Mount
Voltage
125 VDC; 240 VAC; 60 VDC
Durability
20000 Cycles
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Depth (mm)
73
Overall Height (mm)
107
Overall Width (mm)
36
Standards Met
CSA C22.2 No. 5.2; IEC 60947-2; RoHS Compliant; UL 489
Reset Actuator Type
Handle
Schneider Electric - 30 Amp, 125 VDC, 240 VAC, 60 VDC, 1 Pole, DIN Rail Mount, Fixed Mount Miniature Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 73mm Deep x 123mm High x 36mm Wide
Item #: 56785801
Brand: Schneider Electric
Model #: 60249
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
30
Number of Poles
1
Breaking Capacity
10 kA @ 125 VDC; 10 kA @ 240 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC; 6 kA @ 440 VAC
Tripping Mechanism
Thermal-Magnetic
Mounting Type
DIN Rail Mount; Fixed Mount
Voltage
125 VDC; 240 VAC; 60 VDC
Durability
20000 Cycles
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Depth (mm)
73
Overall Height (mm)
123
Overall Width (mm)
36
Standards Met
CSA C22.2 No. 5.2; IEC 60947-2; RoHS Compliant; UL 489
Reset Actuator Type
Handle
Schneider Electric - 30 Amp, 125 VDC, 240 VAC, 60 VDC, 1 Pole, DIN Rail Mount, Fixed Mount Miniature Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 73mm Deep x 81mm High x 18mm Wide
Item #: 69659522
Brand: Schneider Electric
Model #: 60115
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
30
Number of Poles
1
Breaking Capacity
10 kA @ 120 VAC; 10 kA @ 240 VAC; 10 kA @ 60 VDC; 5 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Tunnel
Mounting Type
DIN Rail Mount; Fixed Mount
Voltage
125 VDC; 240 VAC; 60 VDC
Durability
20000 Cycles
Maximum Operating Temperature (F)
140
Minimum Operating Temperature (F)
-13
Overall Depth (mm)
73
Overall Height (mm)
81
Overall Width (mm)
18
Standards Met
CSA C22.2 No. 5.2; IEC 60947-2; RoHS Compliant; UL 489
Reset Actuator Type
Toggle Switch
Schneider Electric - 30 Amp, 125 VDC, 240 VAC, 60 VDC, 3 Pole, DIN Rail Mount, Fixed Mount Miniature Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 73mm Deep x 107mm High x 54mm Wide
Item #: 69659415
Brand: Schneider Electric
Model #: 60198
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
30
Number of Poles
3
Breaking Capacity
10 kA @ 240 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC; 6 kA @ 440 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Tunnel
Mounting Type
DIN Rail Mount; Fixed Mount
Voltage
125 VDC; 240 VAC; 60 VDC
Durability
20000 Cycles
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Depth (mm)
73
Overall Height (mm)
107
Overall Width (mm)
54
Standards Met
CSA C22.2 No. 5.2; IEC 60947-2; RoHS Compliant; UL 489
Reset Actuator Type
Handle
Schneider Electric - 30 Amp, 125 VDC, 240 VAC, 60 VDC, 3 Pole, DIN Rail Mount, Fixed Mount Miniature Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 73mm Deep x 107mm High x 54mm Wide
Item #: 69659423
Brand: Schneider Electric
Model #: 60182
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
30
Number of Poles
3
Breaking Capacity
10 kA @ 240 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC; 6 kA @ 440 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Tunnel
Mounting Type
DIN Rail Mount; Fixed Mount
Voltage
125 VDC; 240 VAC; 60 VDC
Durability
20000 Cycles
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Depth (mm)
73
Overall Height (mm)
107
Overall Width (mm)
54
Standards Met
CSA C22.2 No. 5.2; IEC 60947-2; RoHS Compliant; UL 489
Reset Actuator Type
Handle
Schneider Electric - 30 Amp, 240 VAC, 3 Pole, DIN Rail Mounted Miniature Circuit Breaker - Thermal Magnetic Trip, 20 kA at 240 VAC Breaking Capacity, 14-2 AWG, 76mm Deep x 81mm High x 54mm Wide
Item #: 56785710
Brand: Schneider Electric
Model #: 60282
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
30
Number of Poles
3
Breaking Capacity
20 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
DIN Rail Mounted
Voltage
240 VAC
Wire Size (sq mm)
1-35
Wire Size (AWG)
14-2
Durability
4000 Cycles
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Depth (Decimal Inch)
3
Overall Depth (mm)
76
Overall Height (mm)
81
Overall Height (Decimal Inch)
3.1900
Overall Width (mm)
54
Overall Width (Decimal Inch)
2.1300
Standards Met
CE Marked; CSA C22.2 No. 5.1 Circuit Breakers: File No. 179014; HID (High Intensity Discharge) Rated; IEC 60947-2; UL 489 Circuit Breakers: File No. E215117
Reset Actuator Type
Handle
Schneider Electric - 30 Amp, 240 VAC, 3 Pole, DIN Rail Mounted Miniature Circuit Breaker - Thermal Magnetic Trip, 20 kA at 240 VAC Breaking Capacity, 14-4 AWG, 76mm Deep x 81mm High x 54mm Wide
Item #: 56785694
Brand: Schneider Electric
Model #: 60298
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
30
Number of Poles
3
Breaking Capacity
20 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
DIN Rail Mounted
Voltage
240 VAC
Wire Size (sq mm)
2-25
Wire Size (AWG)
14-4
Durability
4000 Cycles
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Depth (Decimal Inch)
3
Overall Depth (mm)
76
Overall Height (mm)
81
Overall Height (Decimal Inch)
3.1900
Overall Width (mm)
54
Overall Width (Decimal Inch)
2.1300
Standards Met
CE Marked; CSA C22.2 No. 5.1 Circuit Breakers: File No. 179014; HID (High Intensity Discharge) Rated; IEC 60947-2; UL 489 Circuit Breakers: File No. E215117
Reset Actuator Type
Handle
Schneider Electric - 30 Amp, 277 Volt, 1 Pole, Clip Mount C60BP - Branch Protection Circuit Breaker - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-2, 18-3 AWG
Item #: 46119343
Brand: Schneider Electric
Model #: M9F44130
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
C60BP - Branch Protection
Amperage
30
Number of Poles
1
Breaking Capacity
3 kA @ 415 VAC; 10 kA @ 240 VAC; 20 kA @ 60 VDC; 10 kA @ 277 VAC; 14 kA @ 240 VAC; 14 kA @ 120 VAC; 10 kA @ 60 VDC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
Clip
Voltage
277 V
Wire Size (AWG)
18-2; 18-3
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Height (Decimal Inch)
4.0600
Overall Length (Decimal Inch)
2.8300
Overall Width (Decimal Inch)
0.7100
For Use With
OEM Panel
Standards Met
UL 489; IEC; CSA; CCC
Reset Actuator Type
Toggle Switch
Schneider Electric - 30 Amp, 277 Volt, 1 Pole, Clip Mount C60BP - Branch Protection Circuit Breaker - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-2, 18-3 AWG
Item #: 46119780
Brand: Schneider Electric
Model #: M9F43130
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
C60BP - Branch Protection
Amperage
30
Number of Poles
1
Breaking Capacity
3 kA @ 415 VAC; 10 kA @ 240 VAC; 20 kA @ 60 VDC; 10 kA @ 277 VAC; 14 kA @ 240 VAC; 14 kA @ 120 VAC; 10 kA @ 60 VDC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
Clip
Voltage
277 V
Wire Size (AWG)
18-2; 18-3
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Height (Decimal Inch)
4.0600
Overall Length (Decimal Inch)
2.8300
Overall Width (Decimal Inch)
0.7100
For Use With
OEM Panel
Standards Met
UL 489; IEC; CSA; CCC
Reset Actuator Type
Toggle Switch