We ship from multiple warehouses throughout the USA
to get you what you need as fast as possible!
Millions of items in stock!
Fast online checkout - No account required
Cart 0

Products - (25001 Products)


Square D - 125 Amp, 600Y/347 VAC, 3 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 277 VAC, 14 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG


Item #: 41394057
Brand: Square D
Model #: BDL36125LU
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 125
Number of Poles 3
Breaking Capacity 25 kA @ 240 VAC; 18 kA @ 277 VAC; 14 kA @ 600Y/347 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600Y/347 VAC
Wire Size (AWG) 14-3/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type Toggle Switch

$ 1,985.91

Square D - 125 Amp, 600Y/347 VAC, 3 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 VAC, 35 kA at 480 VAC, 18 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG


Item #: 41396607
Brand: Square D
Model #: BGL36125LU
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 125
Number of Poles 3
Breaking Capacity 65 kA @ 240 VAC; 35 kA @ 480 VAC; 18 kA @ 600Y/347 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600Y/347 VAC
Wire Size (AWG) 14-3/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Reset Actuator Type Toggle Switch

$ 2,500.56

Square D - 125 Amp, 600Y/347 VAC, 3 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 VAC, 35 kA at 480 VAC, 18 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG


Item #: 41396565
Brand: Square D
Model #: BGL36125
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 125
Number of Poles 3
Breaking Capacity 65 kA @ 240 VAC; 35 kA @ 480 VAC; 18 kA @ 600Y/347 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600Y/347 VAC
Wire Size (AWG) 14-3/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Reset Actuator Type Toggle Switch

$ 2,245.55

Square D - 125 Amp, 690 VAC, 3 Pole, Fixed Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 86mm Deep x 161mm High x 105mm Wide


Item #: 56741283
Brand: Square D
Model #: LV430631
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 125
Number of Poles 3
Breaking Capacity 10 kA @ 600 VAC; 20 kA @ 480 VAC; 22 kA @ 525 VAC; 25 kA @ 500 VAC; 35 kA @ 440 VAC; 35 kA @ 480 VAC; 36 kA @ 380/415 VAC; 8 kA @ 600 VAC; 8 kA @ 660/690 VAC; 85 kA @ 220/240 VAC; 85 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Mounting Type Fixed
Voltage 690 VAC
Durability 7500 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -31
Overall Depth (mm) 86
Overall Height (mm) 161
Overall Width (mm) 105
Standards Met CSA Certified; EN 60947-2; IEC 60947-2; NEMA AB1; UL 508; UL Listed
Reset Actuator Type Toggle Switch

$ 2,455.27

Square D - 125 Amp, 690 VAC, 4 Pole, Fixed Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 86mm Deep x 161mm High x 140mm Wide


Item #: 56739014
Brand: Square D
Model #: LV430331
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 125
Number of Poles 4
Breaking Capacity 15 kA @ 500 VAC; 20 kA @ 440 VAC; 20 kA @ 480 VAC; 25 kA @ 380/415 VAC; 40 kA @ 220/240 VAC; 40 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Mounting Type Fixed
Voltage 690 VAC
Durability 7500 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -31
Overall Depth (mm) 86
Overall Height (mm) 161
Overall Width (mm) 140
Standards Met CSA Certified; EN 60947-2; IEC 60947-2; NEMA AB1; UL 508; UL Listed
Reset Actuator Type Toggle Switch

$ 3,833.64

Square D - 125 Amp, 690 VAC, 4 Pole, Fixed Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 86mm Deep x 161mm High x 140mm Wide


Item #: 56738982
Brand: Square D
Model #: LV430651
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 125
Number of Poles 4
Breaking Capacity 10 kA @ 600 VAC; 20 kA @ 480 VAC; 22 kA @ 525 VAC; 25 kA @ 500 VAC; 35 kA @ 440 VAC; 35 kA @ 480 VAC; 36 kA @ 380/415 VAC; 8 kA @ 600 VAC; 8 kA @ 660/690 VAC; 85 kA @ 220/240 VAC; 85 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Mounting Type Fixed
Voltage 690 VAC
Durability 7500 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -31
Overall Depth (mm) 86
Overall Height (mm) 161
Overall Width (mm) 140
Standards Met CSA Certified; EN 60947-2; IEC 60947-2; NEMA AB1; UL 508; UL Listed
Reset Actuator Type Toggle Switch

$ 3,833.64

Square D - 125VDC & 500VAC at 50/60 Hz, 3 Pole, Cam & Disconnect Switch - 90mm Wide x 85mm High x 62.5mm Deep


Item #: 56756141
Brand: Square D
Model #: 28902
Exact Tooling IR#: 04

Product Specifications
Amperage 40 @ 500 VAC; 63 @ 220/240 VAC; 63 @ 380/415 VAC; 63 @ 440/480 VAC; 63 @ 500 VAC
Voltage 125 VDC; 500 VAC @ 50/60 Hz
Number of Poles 3
Overall Depth (mm) 62.50
Ingress Protection Rating IP40
Overall Height (mm) 85.00
Overall Width (mm) 90.00
Standards Met CCC; KEMA-KEUR; Utilization Category AC-22A; Utilization Category AC-23A; Utilization Category DC-22A; Utilization Category DC-23A

$ 438.14

Square D - 125VDC & 690VAC at 50/60 Hz, 3 Pole, Cam & Disconnect Switch - 135mm Wide x 100mm High x 62.5mm Deep


Item #: 54526264
Brand: Square D
Model #: 28910
Exact Tooling IR#: 04

Product Specifications
Amperage 125 @ 220/240 VAC; 125 @ 380/415 VAC; 125 @ 440/480 VAC; 125 @ 500 VAC; 125 @ 660/690 VAC; 80 @ 660/690 VAC
Voltage 125 VDC; 690 VAC @ 50/60 Hz
Number of Poles 3
Overall Depth (mm) 62.50
Ingress Protection Rating IP40
Overall Height (mm) 100.00
Overall Width (mm) 135.00
Standards Met CCC; KEMA-KEUR; Utilization Category AC-22A; Utilization Category AC-23A; Utilization Category DC-22A; Utilization Category DC-23A

$ 674.83

Square D - 125VDC & 690VAC at 50/60 Hz, 3 Pole, Cam & Disconnect Switch - 135mm Wide x 100mm High x 62.5mm Deep


Item #: 56770803
Brand: Square D
Model #: 28912
Exact Tooling IR#: 04

Product Specifications
Amperage 100 @ 660/690 VAC; 160 @ 220/240 VAC; 160 @ 380/415 VAC; 160 @ 440/480 VAC; 160 @ 500 VAC; 160 @ 660/690 VAC
Voltage 125 VDC; 690 VAC @ 50/60 Hz
Number of Poles 3
Overall Depth (mm) 62.50
Ingress Protection Rating IP40
Overall Height (mm) 100.00
Overall Width (mm) 135.00
Standards Met CCC; KEMA-KEUR; Utilization Category AC-22A; Utilization Category AC-23A; Utilization Category DC-22A; Utilization Category DC-23A

$ 755.13

Square D - 125VDC & 690VAC at 50/60 Hz, 3 Pole, Cam & Disconnect Switch - 135mm Wide x 100mm High x 62.5mm Deep


Item #: 56756133
Brand: Square D
Model #: 28908
Exact Tooling IR#: 04

Product Specifications
Amperage 100 @ 220/240 VAC; 100 @ 380/415 VAC; 100 @ 440/480 VAC; 100 @ 500 VAC; 100 @ 660/690 VAC; 63 @ 660/690 VAC
Voltage 125 VDC; 690 VAC @ 50/60 Hz
Number of Poles 3
Overall Depth (mm) 62.50
Ingress Protection Rating IP40
Overall Height (mm) 100.00
Overall Width (mm) 135.00
Standards Met CCC; KEMA-KEUR; Utilization Category AC-22A; Utilization Category AC-23A; Utilization Category DC-22A; Utilization Category DC-23A

$ 619.88

Square D - 125VDC & 690VAC at 50/60 Hz, 3 Pole, Cam & Disconnect Switch - 140mm Wide x 136mm High x 96mm Deep


Item #: 56770878
Brand: Square D
Model #: 31106
Exact Tooling IR#: 04

Product Specifications
Amperage 250 @ 220/240 VAC; 250 @ 380/415 VAC; 250 @ 440/480 VAC; 250 @ 500/525 VAC; 250 @ 660/690 VAC
Voltage 125 VDC; 690 VAC @ 50/60 Hz
Number of Poles 3
Overall Depth (mm) 96.00
Ingress Protection Rating IP40
Overall Height (mm) 136.00
Overall Width (mm) 140.00
Standards Met CCC; KEMA-KEUR; Utilization Category AC-22A; Utilization Category AC-23A; Utilization Category DC-22A; Utilization Category DC-23A

$ 1,010.12

Square D - 125VDC & 690VAC at 50/60 Hz, 3 Pole, Cam & Disconnect Switch - 185mm Wide x 205mm High x 130mm Deep


Item #: 54529078
Brand: Square D
Model #: 31114
Exact Tooling IR#: 04

Product Specifications
Amperage 630 @ 220/240 VAC; 630 @ 380/415 VAC; 630 @ 440/480 VAC; 630 @ 500/525 VAC; 630 @ 660/690 VAC
Voltage 125 VDC; 690 VAC @ 50/60 Hz
Number of Poles 3
Overall Depth (mm) 130.00
Ingress Protection Rating IP40
Overall Height (mm) 205.00
Overall Width (mm) 185.00
Standards Met CCC; KEMA-KEUR; Utilization Category AC-22A; Utilization Category AC-23A; Utilization Category DC-22A; Utilization Category DC-22B; Utilization Category DC-23A

$ 2,303.43

Square D - 125VDC & 690VAC at 50/60 Hz, 3 Pole, Cam & Disconnect Switch - 185mm Wide x 205mm High x 130mm Deep


Item #: 56755994
Brand: Square D
Model #: 31110
Exact Tooling IR#: 04

Product Specifications
Amperage 400 @ 220/240 VAC; 400 @ 380/415 VAC; 400 @ 440/480 VAC; 400 @ 500/525 VAC; 400 @ 660/690 VAC
Voltage 125 VDC; 690 VAC @ 50/60 Hz
Number of Poles 3
Overall Depth (mm) 130.00
Ingress Protection Rating IP40
Overall Height (mm) 205.00
Overall Width (mm) 185.00
Standards Met CCC; KEMA-KEUR; Utilization Category AC-22A; Utilization Category AC-23A; Utilization Category DC-22A; Utilization Category DC-23A

$ 1,431.37

Square D - 14-1/0 AWG, Mechanical Transformer Lug Kit - For Use with Single Phase Primary, Single Phase Secondary, Three Phase Delta Primary and Three Phase Delta Secondary Transformers


Item #: 69531713
Brand: Square D
Model #: DASKP100
Exact Tooling IR#: 04

Product Specifications
Transformer Accessory Type Mechanical Lug Kit
For Use With Single-Phase Primary Transformer; Single-Phase Secondary Transformer; Three-Phase Delta Primary Transformer; Three-Phase Delta Secondary Transformer
Wire Size (AWG) 14-1/0

$ 57.64

Square D - 14-1/0, 14-2, 14-2/0 AWG, Mechanical Transformer Lug Kit - For Use with Single Phase Primary and Secondary Transformers, Three Phase Delta with Center Tap, Three Phase Wye Secondary Transformers


Item #: 69529642
Brand: Square D
Model #: DASKGS100
Exact Tooling IR#: 04

Product Specifications
Transformer Accessory Type Mechanical Lug Kit
For Use With Single-Phase Primary & Secondary Transformer; Three-Phase Delta with Center Tap; Three-Phase Wye Secondary Transformer
Wire Size (AWG) 14-1/0; 14-2; 14-2/0

$ 97.56

Square D - 15 Amp, 120 VAC, 1 Pole, Bolt On Residual Current Circuit Breaker with Overcurrent Protection - 14-8 AWG


Item #: 69660975
Brand: Square D
Model #: QOB115GFI
Exact Tooling IR#: 04

Features and Benefits

RCBO (Residual Current Breaker with Over-Current Protection) is a combination of RCD and MCB breakers. They are used for protection against fatal shocks, short circuits and overloads. Current rating is typically up to 40 amperes.
Product Specifications
Circuit Breaker Type Residual Current Circuit Breaker with Overcurrent Protection
Amperage 15
Number of Poles 1
Terminal Connection Type Pressure Plate
Mounting Type Bolt-on
Voltage 120 VAC
Wire Size (AWG) 14-8
Standards Met CSA; RoHS Compliant; UL Listed

$ 343.29

Square D - 15 Amp, 120 VAC, 2 Pole, Bolt On Miniature Circuit Breaker - 14-8 AWG


Item #: 69660587
Brand: Square D
Model #: QOB215SWN
Exact Tooling IR#: 04

Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 15
Number of Poles 2
Terminal Connection Type Pressure Plate
Mounting Type Bolt-on
Voltage 120 VAC
Wire Size (AWG) 14-8
Standards Met CSA; RoHS Compliant; UL Listed

$ 161.27

Square D - 15 Amp, 120/240 VAC, 1 Pole, DIN Rail Mounted, Flush Mount, Surface Mount Miniature Circuit Breaker - Thermal Magnetic Trip, 10 kA at 120/240 VAC Breaking Capacity, 14-2 (Aluminum), 14-2 (Copper) AWG, 74mm Deep x 103mm High x 19mm Wide


Item #: 56788292
Brand: Square D
Model #: QOUR1155283
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 15
Number of Poles 1
Breaking Capacity 10 kA @ 120/240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Pressure Plate
Mounting Type DIN Rail Mounted; Flush Mount; Surface Mount
Voltage 120/240 VAC
Wire Size (AWG) 14-2 (Aluminum); 14-2 (Copper)
Overall Depth (Decimal Inch) 2.9200
Overall Depth (mm) 74
Overall Height (mm) 103
Overall Height (Decimal Inch) 4.0500
Overall Width (mm) 19
Overall Width (Decimal Inch) 3/4
For Use With I-Line Panelboards & Switchboards
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; UL Listed
Reset Actuator Type Toggle Switch

$ 79.21

Square D - 15 Amp, 120/240 VAC, 1 Pole, DIN Rail Mounted, Flush Mount, Surface Mount Miniature Circuit Breaker - Thermal Magnetic Trip, 10 kA at 120/240 VAC Breaking Capacity, 14-2 (Aluminum), 14-2 (Copper) AWG, 74mm Deep x 103mm High x 19mm Wide


Item #: 54530183
Brand: Square D
Model #: QOU115B
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 15
Number of Poles 1
Breaking Capacity 10 kA @ 120/240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Pressure Plate
Mounting Type DIN Rail Mounted; Flush Mount; Surface Mount
Voltage 120/240 VAC
Wire Size (AWG) 14-2 (Aluminum); 14-2 (Copper)
Overall Depth (Decimal Inch) 2.9200
Overall Depth (mm) 74
Overall Height (mm) 103
Overall Height (Decimal Inch) 4.0500
Overall Width (mm) 19
Overall Width (Decimal Inch) 3/4
For Use With I-Line Panelboards & Switchboards
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; UL Listed
Reset Actuator Type Toggle Switch

$ 32.34

Square D - 15 Amp, 120/240 VAC, 1 Pole, DIN Rail Mounted, Flush Mount, Surface Mount Miniature Circuit Breaker - Thermal Magnetic Trip, 10 kA at 120/240 VAC Breaking Capacity, 14-2 (Aluminum), 14-2 (Copper) AWG, 74mm Deep x 103mm High x 19mm Wide


Item #: 56788458
Brand: Square D
Model #: QOUQ115
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 15
Number of Poles 1
Breaking Capacity 10 kA @ 120/240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type DIN Rail Mounted; Flush Mount; Surface Mount
Voltage 120/240 VAC
Wire Size (AWG) 14-2 (Aluminum); 14-2 (Copper)
Overall Depth (Decimal Inch) 2.9200
Overall Depth (mm) 74
Overall Height (mm) 103
Overall Height (Decimal Inch) 4.0500
Overall Width (mm) 19
Overall Width (Decimal Inch) 3/4
For Use With I-Line Panelboards & Switchboards
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; UL Listed
Reset Actuator Type Toggle Switch

$ 57.70