We ship from multiple warehouses throughout the USA
to get you what you need as fast as possible!
Millions of items in stock!
Fast online checkout - No account required
Cart 0

Products - (25001 Products)


Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 87.4mm Deep x 191mm High x 104.7mm Wide


Item #: 56743644
Brand: Square D
Model #: JGL36200T
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Maximum Operating Temperature (F) 104
Overall Depth (Decimal Inch) 3.4400
Overall Depth (mm) 87.40
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met CSA Certified; IEC 647-2 Icu/Ics; NOM; UL Listed
Reset Actuator Type Toggle Switch

$ 3,433.78

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 87.4mm Deep x 191mm High x 104.7mm Wide


Item #: 56743321
Brand: Square D
Model #: JJL36200T
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 100 kA @ 240 VAC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Maximum Operating Temperature (F) 104
Overall Depth (Decimal Inch) 3.4400
Overall Depth (mm) 87.40
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met CSA Certified; IEC 647-2 Icu/Ics; NOM; UL Listed
Reset Actuator Type Toggle Switch

$ 4,935.77

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum) AWG, 127mm Deep x 191mm High x 95.1mm Wide


Item #: 56749161
Brand: Square D
Model #: JDL36200LY
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0 (Aluminum)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Depth (mm) 127
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 95.10
Overall Width (Decimal Inch) 3.7400
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$ 2,155.98

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum) AWG, 127mm Deep x 191mm High x 95.1mm Wide


Item #: 56749153
Brand: Square D
Model #: JDL36200CLC
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0 (Aluminum)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Depth (mm) 127
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 95.10
Overall Width (Decimal Inch) 3.7400
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$ 4,347.86

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum) AWG, 127mm Deep x 191mm High x 95.1mm Wide


Item #: 56744329
Brand: Square D
Model #: JDL36200SN
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0 (Aluminum)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Depth (mm) 127
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 95.10
Overall Width (Decimal Inch) 3.7400
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$ 3,446.87

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum) AWG, 127mm Deep x 191mm High x 95.1mm Wide


Item #: 56744337
Brand: Square D
Model #: JDL36200SK
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0 (Aluminum)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Depth (mm) 127
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 95.10
Overall Width (Decimal Inch) 3.7400
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$ 3,446.87

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum) AWG, 127mm Deep x 191mm High x 95.1mm Wide


Item #: 56744386
Brand: Square D
Model #: JDL36200AASOMA
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0 (Aluminum)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Depth (mm) 127
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 95.10
Overall Width (Decimal Inch) 3.7400
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$ 8,117.65

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum) AWG, 127mm Deep x 191mm High x 95.1mm Wide


Item #: 56749146
Brand: Square D
Model #: JDL36200AASA
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0 (Aluminum)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Depth (mm) 127
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 95.10
Overall Width (Decimal Inch) 3.7400
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$ 4,425.87

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum) AWG, 127mm Deep x 191mm High x 95.1mm Wide


Item #: 56744378
Brand: Square D
Model #: JDL36200AAUO
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0 (Aluminum)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Depth (mm) 127
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 95.10
Overall Width (Decimal Inch) 3.7400
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$ 4,425.87

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum) AWG, 127mm Deep x 191mm High x 95.1mm Wide


Item #: 56744394
Brand: Square D
Model #: JDL36200AA
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0 (Aluminum)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Depth (mm) 127
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 95.10
Overall Width (Decimal Inch) 3.7400
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$ 3,578.29

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 18 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum) AWG, 127mm Deep x 191mm High x 95.1mm Wide


Item #: 56742943
Brand: Square D
Model #: JGL36200LY
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0 (Aluminum)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Depth (mm) 127
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 95.10
Overall Width (Decimal Inch) 3.7400
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$ 4,467.25

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 18 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum) AWG, 127mm Deep x 191mm High x 95.1mm Wide


Item #: 56749435
Brand: Square D
Model #: JGL36200SA
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0 (Aluminum)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Depth (mm) 127
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 95.10
Overall Width (Decimal Inch) 3.7400
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$ 3,890.11

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 18 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum) AWG, 127mm Deep x 191mm High x 95.1mm Wide


Item #: 56743669
Brand: Square D
Model #: JGL36200AB
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0 (Aluminum)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Depth (mm) 127
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 95.10
Overall Width (Decimal Inch) 3.7400
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$ 5,169.44

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 18 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum) AWG, 127mm Deep x 191mm High x 95.1mm Wide


Item #: 56749427
Brand: Square D
Model #: JGL36200AA
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0 (Aluminum)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Depth (mm) 127
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 95.10
Overall Width (Decimal Inch) 3.7400
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$ 4,818.34

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 18 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum), 3/0 (Copper) AWG, 86.6mm Deep x 191mm High x 104.6mm Wide


Item #: 56743651
Brand: Square D
Model #: JGL36200SALU
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0 (Aluminum); 3/0 (Copper)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 3.4100
Overall Depth (mm) 86.60
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 104.60
Overall Width (Decimal Inch) 4.1200
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$ 5,377.50

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 25 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum) AWG, 127mm Deep x 191mm High x 95.1mm Wide


Item #: 56743339
Brand: Square D
Model #: JJL36200SALU
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 25 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0 (Aluminum)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Depth (mm) 127
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 95.10
Overall Width (Decimal Inch) 3.7400
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$ 7,331.54

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 25 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum) AWG, 127mm Deep x 191mm High x 95.1mm Wide


Item #: 56743347
Brand: Square D
Model #: JJL36200SA
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 25 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0 (Aluminum)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Depth (mm) 127
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 95.10
Overall Width (Decimal Inch) 3.7400
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$ 7,268.90

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 25 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum) AWG, 127mm Deep x 191mm High x 95.1mm Wide


Item #: 56749575
Brand: Square D
Model #: JJL36200SOLW
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 25 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0 (Aluminum)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Depth (mm) 127
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 95.10
Overall Width (Decimal Inch) 3.7400
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$ 6,254.76

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 25 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum) AWG, 127mm Deep x 191mm High x 95.1mm Wide


Item #: 56749567
Brand: Square D
Model #: JJL36200LY
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 25 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0 (Aluminum)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Depth (mm) 127
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 95.10
Overall Width (Decimal Inch) 3.7400
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$ 4,291.98

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 50 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum) AWG, 127mm Deep x 191mm High x 95.1mm Wide


Item #: 56742893
Brand: Square D
Model #: JLL36200LV
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 50 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0 (Aluminum)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Depth (mm) 127
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 95.10
Overall Width (Decimal Inch) 3.7400
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$ 8,439.20